Pretty sure this is actually due to not accounting for the factor of -\alpha in the G_0 component of the radiation four-force when switching from the Valencia to the HARM-like formulation. Should be fixed by #104.
Radiation test problems (regardless of closure) run on GPU but are producing errors (including NaN Con2Prims). Tests are failing on GPU.