New entries for 08.hmu.csv #330
Open
JongsmaSimon
wants to merge
3
commits into
john30:master
Choose a base branch
from
JongsmaSimon:Adding-a-lot-of-extra-entries-in-08.hmu.csv
base: master
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
+156
−52
Open
Changes from all commits
Commits
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,52 +1,156 @@ | ||
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment | ||
*r,,,,,,"B511",,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,State,,,,,07,energy,,UCH,,,,,,energy,,kWh,,onoff,,UCH,0=off;1=on,,,state,,UCH,0x01=ready;0x0b=error;0x09=heating;0x11=cooling;0x81=heating_water,, | ||
# Heatpump statistics,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","05FF32",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,EnergyHc,,,,,00,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,EnergyCool,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,Hours,,,,,40,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,HoursHc,,,,,41,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
r,,HoursCool,,,,,43,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# some more statistics from Live Monitor,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,CurrentYieldPower,,,,,23,,,D1B,10,kW,current yielded energy from the environment in kW,,,,,,,,,,,,,,,,,, | ||
r,,CurrentConsumedPower,,,,,24,,,D1B,10,kW,current power consumption of the heatpump in kW,,,,,,,,,,,,,,,,,, | ||
r,,CurrentCompressorUtil,,,,,25,,,D1B,,%,current compressor utilization in percent,,,,,,,,,,,,,,,,,, | ||
# Total heating yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","18",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldTotal,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# Total electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionTotal,,,,,02,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# Ecologic energy Yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","1A01",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
# Electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","1A02",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
# Values from UniTower Test Menu,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B514,05,,,IGN:2,,,,,,,,,,,,,,,,,,,,, | ||
r,,WaterThroughput,,,,,2B03FFFF,,,UIN,,l/h,current heating water flow rate in liters per hour,,,,,,,,,,,,,,,,,, | ||
!include,hcmode.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
!include,errors.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment | ||
*r,,,,,,"B511",,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,State,,,,,07,energy,,UCH,,,,,,energy,,kWh,,onoff,,UCH,0=off;1=on,,,state,,UCH,0x01=ready;0x0b=error;0x09=heating;0x11=cooling;0x81=heating_water,, | ||
# Heatpump statistics,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","05E534",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorHours,,,,,00,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorStarts,,,,,01,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,BuildingPumpHours,,,,,02,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,BuildingPumpStarts,,,,,03,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,4PortValveHours,,,,,06,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,4PortValveSwitches,,,,,07,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,EEVSteps,,,,,0D,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,NoOfSwitchingOps,,,,,30,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,Fan1OperHours,,,,,51,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,Fan1Starts,,,,,52,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,Fan2OperHours,,,,,5E,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,Fan2Starts,,,,,5F,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","05FF32",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldHcDay,,,,,00,,,energy,10,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,YieldCoolingDay,,,,,01,,,energy,10,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,YieldHwcDay,,,,,02,,,energy,10,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,ch_3,,,,,03,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_4,,,,,04,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_5,,,,,05,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_6,,,,,06,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_7,,,,,07,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldHcMonth,,,,,0e,,,energy,10,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,CopHcMonth,,,,,0f,,,UIN,10,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldHc,,,,,10,,,energy,,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,CopHc,,,,,11,,,UIN,10,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldHwcMonth,,,,,12,,,energy,10,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,CopHwcMonth,,,,,13,,,UIN,10,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldHwc,,,,,16,,,energy,,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,CopHwc,,,,,17,,,UIN,10,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_18,,,,,18,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,TargetTempHc,,,,,1C,,,D2C,,°C,Target temperature Hc (°C),,,,,,,,,,,,,,,,,, | ||
# Uncomment the next line if you want to be able to change TargetTempHc (from Home Assistant for example) | ||
#w,hmu,TargetTempHc,,,08,B51A,06B5321C,,,D2C,,°C,Target temperature Hc(°C),,,,,,,,,,,,,,,,,, | ||
r,,ch_1e,,,,,1e,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,SupplyTempWeighted,,,,,1F,,,D2C,10,°C,,,,,,,,,,,,,,,,,,, | ||
r,,FlowTemp,,,,,20,,,D2C,,°C,,,,,,,,,,,,,,,,,,, | ||
r,,Integral,,,,,21,,,SIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,SourceTempInput,,,,,22,,,D2C,,°C,,,,,,,,,,,,,,,,,,, | ||
r,,CurrentYieldPower,,,,,23,,,D1B,10,kW,,,,,,,,,,,,,,,,,,, | ||
r,,CurrentConsumedPower,,,,,24,,,D1B,10,kW,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorUtilization,,,,,25,,,UIN,10,%,,,,,,,,,,,,,,,,,,, | ||
r,,SourceTempOutput,,,,,27,,,D2C,,°C,,,,,,,,,,,,,,,,,,, | ||
r,,BuildingCircuitFlow,,,,,3C,,,UIN,,l/h,,,,,,,,,,,,,,,,,,, | ||
r,,FlowPressure,,,,,3d,,,D2C,4,,,,,,,,,,,,,,,,,,,, | ||
r,,SourcePressure,,,,,3e,,,D2C,4,,,,,,,,,,,,,,,,,,,, | ||
# some more statistics from Live Monitor,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,TotalRunningHours,,,,,40,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,RunningHoursCH,,,,,41,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,RunningHoursCooling,,,,,43,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,RunningHoursHwc,,,,,44,,,UIN,,hours,,,,,,,,,,,,,,,,,,, | ||
r,,ch_46,,,,,46,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_49,,,,,49,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_4a,,,,,4a,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_4b,,,,,4b,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,ch_4c,,,,,4c,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
r,,TotalEnergyUsage,,,,,4D,,,energy,,kWh,,,,,,,,,,,,,,,,,,, | ||
r,,ch_63,,,,,63,,,UIN,,,,,,,,,,,,,,,,,,,,, | ||
# Heat pump configuration menu values | ||
*r,,,,,,"B51A","058F35",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,HeatCurve,,,,,2D,,,BCD,10,,heat curve 0.1 to 4.0,,,,,,,,,,,,,,,,,, | ||
# Uncomment the next line if you want to be able to change HeatCurve (from Home Assistant for example) | ||
#w,hmu,HeatCurve,,,08,B51A,06CD352D,,,BCD,10,,,,,,,,,,,,,,,,,,,, | ||
r,,SummerSwitchOffTemp,,,,,2E,,,D2C,,°C,Switch-off temperature summer (°C),,,,,,,,,,,,,,,,,, | ||
r,,HcBivalencePoint,,,,,2F,,,D2C,,°C,Central heating bivalence point (°C),,,,,,,,,,,,,,,,,, | ||
r,,HwcBivalencePoint,,,,,30,,,D2C,,°C,Bivalence point domestic hot water (°C),,,,,,,,,,,,,,,,,, | ||
r,,MaxFlowTemp,,,,,32,,,D2C,,°C,Maximum flow temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,MinFlowTemp,,,,,33,,,D2C,,°C,Minimum flow temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,HcModeActive,,,,,34,,,UCH,0=no;1=yes,,Central heating mode active (yes/no),,,,,,,,,,,,,,,,,, | ||
r,,HwcModeActive,,,,,35,,,UCH,0=no;1=yes,,Domestic hot water mode active (yes/no),,,,,,,,,,,,,,,,,, | ||
r,,HwcChargeHysteresis,,,,,39,,,D2C,,°K,Hysteresis Hwc charging (°K),,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","05C433",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,ImmersionHeaterMode,,,,,1E,,,UCH,0=off;1=on,,Immersion heater mode (on/off),,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","05F834",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorHysteresisHc,,,,,43,,,D2C,,°K,Compressor hysteresis central heating (°K),,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","058635",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,CompressorHysteresisCooling,,,,,3F,,,D2C,,,Compressor hysteresis cooling (°K),,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","055234",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,HwcMode,,,,,44,,,UCH,0=eco;1=normal;2=balance,,Domestic hot water mod (eco/normal/balance),,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B51A","05C632",,,IGN:3,,,,,,,,,,,,,,,,,,,,, | ||
r,,TargetTempHwc,,,,,07,,,D2C,,°C,Target Hwc temperature (°C),,,,,,,,,,,,,,,,,, | ||
# Uncomment the next line if you want to be able to change TargetTempHwc (from Home Assistant for example) | ||
#w,hmu,TargetTempHwc,,,08,B51A,06783207,,,D2C,,°C,Target Hwc temperature (°C),,,,,,,,,,,,,,,,,, | ||
# Total heating yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","18",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldTotal,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# Total electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionTotal,,,,,02,,,energy,,,,,,,,,,,,,,,,,,,,, | ||
# Ecologic energy Yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","1A01",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,YieldThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,YieldThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
# Electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,"B516","1A02",,,IGN:1,,,,,,,,,,,,,,,,,,,,, | ||
r,,ConsumptionThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
r,,ConsumptionThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,, | ||
# Values from VWZ AI Plus Test Menu,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
*r,,,,,,B514,05,,,IGN:2,,,,,,,,,,,,,,,,,,,,, | ||
#(query to WP entries Installer level/Test Menu/Sensor test) | ||
r,,BuildingCircuitPumpPower,,,,,0103FFFF,,,UIN,,%,Building circuit pump power (% of maximum),,,,,,,,,,,,,,,,,, | ||
r,,Fan1,,,,,1103FFFF,,,UIN,,%,Fan 1 speed (% of max),,,,,,,,,,,,,,,,,, | ||
r,,Fan2,,,,,1203FFFF,,,UIN,,%,Fan 2 speed (% of max),,,,,,,,,,,,,,,,,, | ||
r,,CondensateTrayHeater,,,,,1303FFFF,,,onoff,,,Condensate tray heater (on/off),,,,,,,,,,,,,,,,,, | ||
r,,4PortValve,,,,,1403FFFF,,,onoff,,,Four way valve (on/off),,,,,,,,,,,,,,,,,, | ||
r,,PositionEEV,,,,,1503FFFF,,,UIN,,%,Position EEV (%),,,,,,,,,,,,,,,,,, | ||
r,,HeatingCoilCompressor,,,,,1703FFFF,,,onoff,,,Heating coil compressor (on/off),,,,,,,,,,,,,,,,,, | ||
r,,SupplyTemp,,,,,2803FFFF,,,temps2,10,°C,Supply temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,ReturnTemp,,,,,2903FFFF,,,temps2,10,°C,Return temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,BuildingCircuitWaterPressure,,,,,2A03FFFF,,,UIN,10,bar,Gebouwcircuit waterPressure (bar),,,,,,,,,,,,,,,,,, | ||
r,,WaterThroughput,,,,,2B03FFFF,,,UIN,,l/h,Current heating water flow rate (liter/hour),,,,,,,,,,,,,,,,,, | ||
r,,AirInletTemp,,,,,3003FFFF,,,temps2,10,°C,Air inlet temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,CompressorOutletTemp,,,,,3703FFFF,,,temps2,10,°C,Compressor outlet temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,CompressorInletTemp,,,,,3803FFFF,,,temps2,10,°C,Compressor inlet temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,EEVOutletTemp,,,,,3903FFFF,,,temps2,10,°C,EEV outlet temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,CondensorOutletTemp,,,,,3B03FFFF,,,temps2,10,°C,Condensor outlet temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,HighPressure,,,,,3F03FFFF,,,UIN,10,bar,High pressure (bar),,,,,,,,,,,,,,,,,, | ||
r,,LowPressure,,,,,4003FFFF,,,UIN,10,bar,Low pressure (bar),,,,,,,,,,,,,,,,,, | ||
r,,HighPressureSwitch,,,,,4303FFFF,,,UCH,0=open;1=closed,,High pressure switch (open/closed),,,,,,,,,,,,,,,,,, | ||
r,,EvaporationTemp,,,,,5503FFFF,,,temps2,10,°C,Evaporation temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,CondensationTemp,,,,,5603FFFF,,,temps2,10,°C,Condensation temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,OverheatingTargetValue,,,,,5703FFFF,,,temps2,10,°K,Overheating target temperature (°K),,,,,,,,,,,,,,,,,, | ||
r,,OverheatingActualValue,,,,,5803FFFF,,,temps2,10,°K,Overheating temperature actual (°K),,,,,,,,,,,,,,,,,, | ||
r,,SubcoolingTargetValue,,,,,5903FFFF,,,temps2,10,°K,Subcooling target temperaturee (°K),,,,,,,,,,,,,,,,,, | ||
r,,SubcoolingActualValue,,,,,5A03FFFF,,,temps2,10,°K,Subcooling temperature actual (°K),,,,,,,,,,,,,,,,,, | ||
r,,CompressorSpeed,,,,,5D03FFFF,,,UIN,10,Hz,Compressor speed (rps),,,,,,,,,,,,,,,,,, | ||
r,,TemperatureSwitchCompressorOutlet,,,,,7B03FFFF,,,UCH,0=open;1=closed,,,,,,,,,,,,,,,,,,,, | ||
#(query to VWZ AI+ e.g. device 76, adapt for MEH if deviceno differs from 76) | ||
r,,ThreeWayValve,,,76,,0203FFFF,,,UCH,0=heating;1=dhw,,Three way valve (heating/dhw),,,,,,,,,,,,,,,,,, | ||
r,,HwcTemp,,,76,,2C03FFFF,,,temps2,10,°C,Hwc temperature (°C),,,,,,,,,,,,,,,,,, | ||
r,,OutdoorTemp,,,76,,4503FFFF,,,temps2,10,°C,Outdoor temperature (°C),,,,,,,,,,,,,,,,,, | ||
!include,hcmode.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, | ||
!include,errors.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, |
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
For HMU00;0607;5103, UIN,16 is dead-on for me. UIN,10 gives me readings up to around 110%.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
For my split system it is:
r,,CompressorModulation,,,,,25,,,D2C,,%,,,,,,,,,,,,,,,,,,,
Readings then match with the 'Live Monitor'.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
D2C also works fine for me.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@pulquero : what type of system do you have? I also have a split, so could change the register to D2C as proposed, but don't want to create issues for owners of a monoblock.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
7kw aroTHERM plus Mono
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
thanks for confirming. i've updated the registor in my repository