Add an option to run thermodilution. Display readings in a pop-up window. Values should be pulled from PatientEditor's "advanced hemodynamics" section.
Will need patient height & weight (-> BSA) for indices.
Add an option to run thermodilution. Display readings in a pop-up window. Values should be pulled from PatientEditor's "advanced hemodynamics" section.
Will need patient height & weight (-> BSA) for indices.
Display:
CO (4-8 L/min) ... 4-8 L/min
CI? = CO / BSA ... 2.5 - 4.0 L/min/m2
SV = CO / HR * 1000 ... 50-100 ml/beat
SI? = CI / HR * 1000 ... 25-45 ml/beat/m2
SVR = MAP - CVP / CO * 80 ... 800-1200 dynes/s/cm-5
PVR = MPAP - PDP / CO * 80 ... 50-250 dynes/s/cm-5