expression: fix wrong calculation order of radians
(#57672)
#57687
+5
−3
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
This is an automated cherry-pick of #57672
What problem does this PR solve?
Issue Number: close #57671 close #57661
Problem Summary:
See #57671
What changed and how does it work?
radians changes from
arg * PI / 180
toarg * (PI / 180)
to avoid infinite float and wrong result issues. FYI: https://github.com/mysql/mysql-server/blob/ee079e5ca930ce5ed0643326abadeed8cd41fffc/sql/item_func.h#L1556 MySQL also calculatesPI / 180
firstly.TiKV has already fixed this bug in tikv/tikv#17853.