Using the Ballard MIL-STD-1553 Custom Device

This guide demonstrates how to configure and deploy the Ballard MIL-STD-1553 custom device. Using simulated Bus Controller and Remote Terminals on the Ballard MIL-STD-1553 PXIe module, it is possible to use the custom device to send and receive data without external wiring.

Configure the Ballard MIL-STD-1553 Hardware

The custom device targets one core of a Ballard MIL-STD-1553 PXI module. To target multiple modules or multiple cores on the same module, you must use multiple instances of the custom device.

A valid hardware configuration for the core must be provided to each instance of the custom device. The hardware configuration is provided by an XML file that adheres to Ballard's schema, referred to here as the Hardware XML file. Ballard's driver includes the BTI XML Editor application to generate valid hardware configurations.

BTI XML Editor

A simple Hardware XML file is included for getting started with the custom device.

Configure the Custom Device

This guide shows two options for configuring the custom device:

  • Importing a Parameters file in System Explorer
  • Scripting the custom device configuration

Importing a Parameters file in System Explorer

The Parameters file is generated from an XML schema for configuring the custom device. It must match the Hardware XML file's configuration for the Ballard hardware. More information about the Parameters file XML schema can be found in Docs/Parameters XML File/Parameters XML File.md.

This example uses simple example Parameters and Hardware files found in the Assets directory:

  • Assets/Parameters.xml
  • Assets/Hardware.xml

The files are configured with a simulated bus controller and 2 simulated remote terminals:

  • X: Bus Controller
  • 1: Remote Terminal 1
  • 2: Remote Terminal 2

These terminals send and receive messages of each type supported by the Custom Device:

  • BC to RT - Bus Controller to Remote Terminal.
  • RT to BC - Remote Terminal to Bus Controller.
  • RT to RT - Remote Terminal to Remote Terminal.
  • MC - Mode Code.

Each pair of messages (BC to RT, RT to BC, and RT to RT) are configured with similar settings. Message BC to RT1 (SA2) does not define parameters under the message, which will result in VeriStand channels for as many U16 datatype words as are found in the <numberOfWords> tag. Message BC to RT15 (SA3) defines two unscaled 32-bit parameters with BNR encoding, one signed and the other unsigned. Below is the configuration of the two BC to RT messages:

		<message>
			<name>BC to RT1 (SA2)</name>
			<address>
				<terminalAddress>1</terminalAddress>
				<subAddress>2</subAddress>
				<direction>Rx</direction>
			</address>
			<messageType>BC to RT</messageType>
			<numberOfWords>4</numberOfWords>
			<createTimestampChannel>true</createTimestampChannel>
		</message>
		<message>
			<name>BC to RT15 (SA3)</name>
			<address>
				<terminalAddress>15</terminalAddress>
				<subAddress>3</subAddress>
				<direction>Rx</direction>
			</address>
			<messageType>BC to RT</messageType>
			<numberOfWords>4</numberOfWords>
			<createTimestampChannel>true</createTimestampChannel>
			<parameters>
				<parameter>
					<encoding>BNR</encoding>
					<signed>true</signed>
					<startBit>0</startBit>
					<numberOfBits>32</numberOfBits>
					<scale>1</scale>
					<offset>0.0</offset>
					<name>Parameter 0</name>
					<defaultValue>0</defaultValue>
				</parameter>
				<parameter>
					<encoding>BNR</encoding>
					<signed>false</signed>
					<startBit>32</startBit>
					<numberOfBits>32</numberOfBits>
					<scale>1</scale>
					<offset>0.0</offset>
					<name>Parameter 1</name>
					<defaultValue>0</defaultValue>
				</parameter>
			</parameters>
		</message>

For each message in the Parameters configuration file, the Custom Device creates corresponding VeriStand channels under the simulated terminals contained in the file. For these two example messages, the Bus Controller has the Tx channels, so the words and parameters under the Bus Controller are outputs. Corresponding input channels are created under Remote Terminal 1 and Remote Terminal 15. The resulting System Definition tree and screen contents can be seen in later sections of this guide.

Configure the Custom Device in System Explorer

  1. Create a new VeriStand Project and configure your PXI Linux RT target.
  2. Navigate to the Targets\Controller\Hardware\Custom Devices entry in the tree.
  3. Right-click the Custom Devices entry and add a new instance of the NI\Ballard MIL-STD-1553 custom device.
  4. Use the Main Page to set the PXI Slot Number and Core Number accordingly. System Explorer Main Page
  5. Navigate to the Configuration Files page.
  6. Use the browse button next to each box to select the example files used for this example.
    1. Hardware file: niveristand-ballard-milStd1553-custom-device\Docs\User Guide\Assets\Hardware.xml
    2. Parameters file: niveristand-ballard-milStd1553-custom-device\Docs\User Guide\Assets\Parameters.xml System Explorer Configuration Files

Note: After configuring the custom device, all of the configuration under Channel is read-only except for the Description field on each page.

System Explorer Parameter

Scripting the Custom Device Configuration

The Ballard MIL-STD-1553 custom device includes a LabVIEW scripting API to configure the custom device programmatically. This allows users to parse an existing MIL-STD-1553 database into a working custom device configuration without the need to create a Parameters file. It also allows importing a Parameters file programmatically instead of through System Explorer.

To use the scripting API, the optional scripting package must be installed: ni-ballard-mil-std-1553-veristand-20xx-labview-support

The scripting API includes two example files inside a LabVIEW example project found at the following directory: C:\Program Files (x86)\National Instruments\LabVIEW 20xx\examples\NI VeriStand Custom Devices\Ballard MIL-STD-1553. It contains two example VIs:

  • Import Parameters Configuration to New Ballard MIL-STD-1553 Custom Device.vi - Demonstrates using the Ballard MIL-STD-1553 scripting API to configure the custom device by importing a parameters configuration file.
  • Build New Ballard MIL-STD-1553 Custom Device.vi - Demonstrates using the Ballard MIL-STD-1553 scripting API to configure the custom device by building from configuration clusters.

Scripting Examples Project

Deploy the System Definition

After configuring the System Definition with the custom device, deploy the System Definition using VeriStand. Once the deployment state reaches Connected, use a VeriStand screen to display the custom device inputs and outputs. This example uses VeriStand 2020 R5, so your screen controls may behave differently depending on version.

  1. Open a VeriStand Screen
  2. Highlight the System Definition tree in the left rail
  3. Expand the tree to Targets\Controller\Hardware\Custom Devices\Ballard MIL-STD-1553\CH00
  4. Drag the Bus Controller\BC to RT1 (SA2) item onto the screen
  5. Drag the Remote Terminal 01\Subaddress 02 item onto the screen
  6. Change the values written to the words in the outgoing message (Bus Controller\BC to RT1 (SA2)\Word 0x) and see the values received by the Remote Terminal

VeriStand Screen

This example set of Hardware and Parameters files contains other message types, as well as Acyclic Frames. The minor frame that sends the RT to RT messages is tied to the frame trigger in the system definition. To send the RT to RT messages, toggle the Bus Controller\Acyclic Frames\Trigger (acyclicFrame ID24) value to non-zero.

Modifying the Custom Device Configuration

Once the custom device is configured, you can change the configuration using the Configuration Files page in System Explorer. If the Parameters file changes on disk, use the Refresh button. If you need to select a new file, press the button to load a new path into the dialog.

Each time the configuration is changed, the Ballard MIL-STD-1553 Refresh dialog will be displayed to compare the current and new configurations. Press Apply to accept the changes, or Cancel to exit without reconfiguring.

Refresh Dialog