Notifications
You must be signed in to change notification settings - Fork 71
/
modbus-sungrow-sg7rt.py
208 lines (204 loc) · 9.56 KB
/
modbus-sungrow-sg7rt.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
"""
Model, Type code, MPPT, String/MPPT
SG7.0RT 0x243C 2 2;1
"""
read_register = {
# "5000": "device_type_code", # Inverter Model, See Appendix 6
"5001": "nominal_active_power_10", # 0.1kW > kW - Max kW Inverter can run at
# "5002": "output_type", # 0=2P, 1=3P4L, 2=3P3L
"5003": "daily_power_yield_10", # 0.1 kWh > kWh - Daily, Energy generated (PVOutput: Energy Generation)
# "5004": "total_power_yield_1000", # kWh > MWh - accuracy to 1 (use 5114)
"5006": "total_ongrid_running_time", # hr
"5008": "internal_temp_10", # 0.1C > C
"5009": "apparent_power_1000", # 0.1Va > KVa - From Inverter to Grid/Home
"5011": "mppt1_voltage_10", # 0.1V > V
"5012": "mppt1_current_10", # 0.1A > A
"5013": "mppt2_voltage_10", # 0.1V > V
"5014": "mppt2_current_10", # 0.1A > A
# "5015": "mppt3_voltage_10", # 0.1V > V
# "5016": "mppt3_current_10", # 0.1A > A
"5017": "total_pv_power", # W - From Panels to Inverter
"5019": "phase_voltage_a_10", # 0.1V > V
"5020": "phase_voltage_b_10", # 0.1V > V
"5021": "phase_voltage_c_10", # 0.1V > V
"5022": "phase_current_a_10", # 0.1A > A
"5023": "phase_current_b_10", # 0.1A > A
"5024": "phase_current_c_10", # 0.1A > A
# "5025": - 5030: Reserved, All scan at xFF xFF
"5031": "total_active_power", # W - Current, Inverter to Grid/Home (PVOutput: Power Generation)
"5033": "total_reactive_power", # W
"5035": "power_factor", # >0 leading, <0 lagging
"5036": "grid_frequency_10", # 0.1Hz > Hz (Use 5148)
# "5037": Reserved
"5037": "unknown_aa", # TBD
# "5038": "work_state1", # See Appendix 1. 5039-5045 Fault Date+time
# "5046": - 5048: Reserved, All scan at x00 x00
"5049": "nominal_reactive_power", # 0.1kV
# "5071": "array_insulation_resistance_10",# k-ohm
# "5072": - 5076: Reserved, All scan at xFF xFF
# "5077": "active_power_reg_setpoint_1000",# 1w > kW
# "5079": "reactive_power_reg_setpoint", # 1Va
# "5081": "work_state2", # See Appendix 2.
# Meter power 5083 - 5104
"5083": "meter_power_overflow", # 1w - (65535 - meter_power) = Inverter to Grid
"5084": "meter_power_indicator", # 1w
# "5085": "meter_phase_a", # 1w
# "5087": "meter_phase_b", # 1w
# "5089": "meter_phase_c", # 1w
"5091": "meter_load_power", # 1w - meter_load_power = Grid to House
# "5093": "meter_daily_export", # 0.1Kw
# "5095": "meter_total_export", # 0.1Kw
# "5097": "meter_daily_import", # 0.1Kw
# "5099": "meter_total_import", # 0.1Kw
# "5101": "meter_daily_consumption", # 0.1Kw
# "5103": "meter_toal_consumption", # 0.1Kw
"5113": "daily_operation_time", # 1m
# "5114": "present_country", # See Appendix 4
# "5115": "mppt4_voltage_10", # 0.1V > V
# "5116": "mppt4_current_10", # 0.1A > A
# "5117": "mppt5_voltage_10", # 0.1V > V
# "5118": "mppt5_current_10", # 0.1A > A
# "5119": "mppt6_voltage_10", # 0.1V > V
# "5120": "mppt6_current_10", # 0.1A > A
# "5121": "mppt7_voltage_10", # 0.1V > V
# "5122": "mppt7_current_10", # 0.1A > A
# "5123": "mppt8_voltage_10", # 0.1V > V
# "5124": "mppt8_current_10", # 0.1A > A
# "5125": - 5027: Reserved
"5128": "monthly_power_yields_10", # 0.1kW
# "5130": "mppt9_voltage_10", # 0.1V > V
# "5131": "mppt9_current_10", # 0.1A > A
# "5132": "mppt10_voltage_10", # 0.1V > V
# "5133": "mppt10_current_10", # 0.1A > A
# "5134": "mppt11_voltage_10", # 0.1V > V
# "5135": "mppt11_current_10", # 0.1A > A
# "5136": "mppt12_voltage_10", # 0.1V > V
# "5137": "mppt12_current_10", # 0.1A > A
# "5138": - 5143: Reserved
"5144": "total_power_yield_10000", # 0.1kWh > MWh - Higher Accuracy (See: 5004)
"5146": "negative_voltage_to_ground", # 0.1V
"5147": "bus_voltage", # 0.1V
"5148": "grid_frequency_100", # 0.01Hz > Hz - Higher Accuracy (See: 5036)
# "5149": Reserved, All scan at xFF xFF
# "5150": "pid_work_state", # 2: PID Recover Operation, 4: Anti-PID Operation, 8: PID Abnormity
# "5151": "pid_alarm_code", # 432:PID resistance abnormal 433:PID function abnormal 434:PID overvoltage/overcur rent protection
# "5152": - 7012: Reserved
"5216": "export_power_overflow", # W - House Grid Consumption (+ = importing, - = exporting) #new read register
"5217": "export_power_indicator", # W - House Grid Consumption Overflow Indicator #new read register
"5218": "power_meter", # W - House Overall Consumption
"5220": "unknown_cb", # TBD
"5221": "unknown_cc", # TBD
"5222": "unknown_cd", # TBD
# "5223": "x_daily_power_yield", # Seems to be: 5003: daily_power_yield
# "5224": "x_monthly_power_yields", # Seems to be: 5128: monthly_power_yields
# "5226": "x_total_power_yield", # Seems to be: 5144: total_power_yield
# "5228": "x_total_power_yield", # Seems to be: 5144: total_power_yield
# "5230": "x_total_ongrid_running_time", # Seems to be: 5006: total_ongrid_running_time
# "5232": "x_apparent_power", # Seems to be: 5009: apparent_power
"5234": "unknown_cm", # TBD
"5235": "unknown_cn", # TBD
# "5236": "x_total_pv_power", # Seems to be: 5017: total_pv_power
# "5238": "x_apparent_power", # Seems to be: 5009: apparent_power
# "5240": "x_daily_operation_time", # Seems to be: 5113: daily_operation_time
# "5241": "x_power_factor", # Seems to be: 5035: power_factor
# "5242": "x_grid_frequency", # Seems to be: 5148: grid_frequency
# "5243": "x_negative_voltage_to_ground", # Seems to be: 5146: negative_voltage_to_ground
# "5244": "x_bus_voltage", # Seems to be: 5147: bus_voltage
# "5245": "x_internal_temp", # Seems to be: 5008: internal_temp
# "5246": "x_array_insulation_resistance", # Seems to be: 5071: array_insulation_resistance
# "5247": "x_phase_voltage_a", # Seems to be: 5019: phase_voltage_a
# "5248": "x_phase_voltage_b", # Seems to be: 5020: phase_voltage_b
# "5249": "x_phase_voltage_c", # Seems to be: 5021: phase_voltage_c
# "5250": "x_phase_current_a", # Seems to be: 5022: phase_current_a
# "5251": "x_phase_current_b", # Seems to be: 5023: phase_current_b
# "5252": "x_phase_current_c", # Seems to be: 5024: phase_current_c
# "7013": "string_1_current", # 0.01A
# "7014": "string_2_current", # 0.01A
# "7015": "string_3_current", # 0.01A
# "7016": "string_4_current", # 0.01A
# "7017": "string_5_current", # 0.01A
# "7018": "string_6_current", # 0.01A
# "7019": "string_7_current", # 0.01A
# "7020": "string_8_current", # 0.01A
# "7021": "string_9_current", # 0.01A
# "7022": "string_10_current", # 0.01A
# "7023": "string_11_current", # 0.01A
# "7024": "string_12_current", # 0.01A
# "7025": "string_13_current", # 0.01A
# "7026": "string_14_current", # 0.01A
# "7027": "string_15_current", # 0.01A
# "7028": "string_16_current", # 0.01A
# "7029": "string_17_current", # 0.01A
# "7030": "string_18_current", # 0.01A
# "7031": "string_19_current", # 0.01A
# "7032": "string_20_current", # 0.01A
# "7033": "string_21_current", # 0.01A
# "7034": "string_22_current", # 0.01A
# "7035": "string_23_current", # 0.01A
# "7036": "string_24_current" # 0.01A
}
holding_register = {
"5000": "year",
"5001": "month",
"5002": "day",
"5003": "hour",
"5004": "minute",
"5005": "second",
"5006": "start_stop", # 0xCF (Start) 0xCE (Stop)
# "5007": "power_limitation_switch", # 0xAA: Enable; 0x55: Disable
# "5008": "power_limitation_setting", # See Appendix 6
# "5009": Reserved
# "5010": "export_power_limitation", # 0xAA: Enable; 0x55: Disable
# "5011": "export_power_limitation_value", # Export power limitation value
# "5012": "current_transformer_output_cur",# 1-100
# "5013": "current_transformer_range", # 1-10000
# "5014": "current transformer", # 10- Internal 1- External
# "5015": "export_power_limitation_perc", # 1-1000
# "5016": "installed_pv_power", # 1-30000
# "5019": "power_factor_setting", # 1-10000
# "5020": "schedule_achieve_ol", # 0xAA: Enable; 0x55: Disable
# "5021": - 5033: Reserved
# "5035": "night_svg_switch", # 0xAA: Enable; 0x55: Disable
# "5036": "reactive_power_adjustment_mode", #
# "5037": "reactive_power_perc_setting", # -1000 to 1000
# "5038": Reserved
# "5039": "power_limitation_adjustment", # See Appendix 6
# "5040": "reactive_power_adjustment", # See Appendix 6
# "5040": "pid_recovery", # 0xAA: Enable; 0x55: Disable
# "5042": "anti_pid", # 0xAA: Enable; 0x55: Disable
# "5043": "full_day_pid_suppression", # 0xAA: Enable; 0x55: Disable
# "5044": - 5047: Reserved
# "5049": - 5154 - Q(U) Curve
# "5155": - 5199: Reserved
}
scan = """{
"read": [
{
"start": "4999",
"range": "100"
},
{
"start": "5099",
"range": "100"
},
{
"start": "5199",
"range": "100"
}
],
"holding": [
{
"start": "4999",
"range": "20"
}
]
}"""
# Match Modbus registers to pvoutput api fields
# Reference: https://pvoutput.org/help.html#api-addstatus
pvoutput = {
"Energy Generation": "daily_power_yield",
"Power Generation": "total_active_power",
"Power Consumption": "meter_load_power",
"Temperature": "internal_temp",
"Voltage": "phase_voltage_b"
}