I don't have an answer, but seeing this pop up in my email prompted me to think about the configuration interface when you log into your powerwall as installer (as I used to do when that was possible without toggling the switch on the side) to control charging mode, and go through the configuration wizard. Typically (at least here in Australia, but I assume from reading the installation manuals, globally), they are configured with one CT for grid connection (per phase), and once CT for solar generation (per phase). Everything else reported from /api/meters/aggregates is derived from internal metering for the powerwall, and in particular home usage is a derived calculation based on site (the grid CT or CTs) based on the result of the net of solar, PW and site. So this means that you should be able to re-derive the source of the data assuming it hasn't been lost between pypowerwall, telegraf and grafana. Hopefully this has helped. Let me know if I can help (or test). |
Edit: I realised this doesn't help with the underlying problem. It's just a different version of the solar integral. A reminder that I shouldn't post just before bed after a long day! I'd suggest taking a closer look at differences in the cumulative On topic - while I was waiting for the meter changeover, I did some preliminary checks of inverter output vs solar output from the gateway cumulatives. Over a 20 day period, the inverters had an output of 693.1 kWh vs 692.4 as measured by the Tesla - so a difference of 0.7 kWh where I had a measurement error of up to 1kWh on one of the inverter meters, which I thought was not too bad! Since the meter changeover, I've been using a more precise value from both inverters - +/- 0.1 kWh on each. With only 7 days of data, I have 278kWh generated with a difference of 0.1 kWh between the inverter meters and the Tesla reading. I'd like more data to confirm, but at first glance it's looking as though this can be a reasonably accurate way to capture solar output. |
That's great about the meter changeover! I just realized that I can compute the "grid_to_pw" value with the rest of values we are gathering. grid_to_pw = positive_values_only ( from_grid - home - solar )
The resulting show the charge from grid event: Showing only the "grid_to_pw" flows: Now what to do with that to fix the "Self Power Data"! 🤣 |
The self-powered issue is tricky. If you zoom into the period right after the grid_to_pw event, then you will see a bunch of energy coming from the battery and you'll be counting that as 'From Powerwall" which I think generally comes with an assumption that energy from the Powerwall is NOT grid power. So the next day you might show nothing but "From Solar" and "From Powerwall" with zero grid use, but that isn't really accurate. I don't see any reasonable way to work around that. I do like the grid_to_pw in red... I'm going to add that to my usage panels, but I think the zero (or maybe near-zero) values need to be hidden because it put a red line across the entire chart. |
I had been using mean values with a group by time($__interval), so I added that to the query. I also noticed that the query you posted didn't show any power going to the grid, so I changed the "Grid Usage" part to be: mean(from_grid) - mean(to_grid") as grid The whole query is: SELECT mean(solar) as solar , mean(home) as home, mean(from_grid) - mean(to_grid) as grid,
mean(from_pw) as from_pw, -mean(to_pw) as to_pw,
((mean(from_grid) - mean(home) - mean(solar)) + ABS((mean(from_grid) - mean(home) - mean(solar)))) / 2 AS "grid_to_pw"
FROM autogen.http WHERE $timeFilter group by time($__interval) fill(none) Here's a stormwatch event followed by an outage back in July: After that I decided to also show the power going to the Powerwall from the event in a different color by adding another query: SELECT -((mean(from_grid) - mean(home) - mean(solar)) + ABS((mean(from_grid) - mean(home) - mean(solar)))) / 2 AS pw_from_grid
from autogen.http where (((from_grid - home - solar) + ABS(from_grid - home -solar)) / 2) > 250
and $timeFilter GROUP BY time($__interval) fill(null) The ">250" is to filter out small values that aren't from a grid charging event. I set a field override for this field to make it orange, not very transparent, and hide it in the legend. I also hid the "grid_to_pw" from the legend: Applying the 'where >250' to both sides of the grid charging event has the effect of removing the red line at or near the zero point, so I separated this into 2 queries, one that gets the grid charging events (over 250 watts) and one that gets everything else: SELECT mean(solar) as solar, mean(home) as home, mean(from_grid) - mean(to_grid) as grid,
mean(from_pw) as from_pw, -mean(to_pw) as to_pw
FROM autogen.http WHERE $timeFilter group by time($__interval) fill(none)
SELECT ((mean(from_grid) - mean(home) - mean(solar)) + ABS((mean(from_grid) - mean(home) - mean(solar)))) / 2 AS "grid_to_pw",
-((mean(from_grid) - mean(home) - mean(solar)) + ABS((mean(from_grid) - mean(home) - mean(solar)))) / 2 AS pw_from_grid
FROM autogen.http WHERE
(((from_grid - home - solar) + ABS(from_grid - home -solar)) / 2) > 250
and $timeFilter GROUP BY time($__interval) fill(null) |
One possibility is to track the inflow, accumulation and withdrawal of grid energy and solar energy separately. But it leads to pretty ugly accounting. |
Thanks @BJReplay for the validation through many examples! And @youzer-name you are a Grafana wizard! I always learn some better way to visualize the data through your notes. Thank you! On the "Self-Power" panel update... this panel is used to give you a percentage breakdown of what is powering your home. It is broken down into 3 buckets: Solar, Powerwall and Grid SolarThe basic premise for computing "Self-Power" by solar is: Solar_SelfPower = solar - to_pw - to_grid This assumes that the only way to charge a Powerwall is via Solar, as such we remove any power sent to Powerwall or to Grid as they are not providing immediate "Self-Power" for the home. However, a miscalculation happens if the Powerwall is charged by the Grid. As discussed above, we can compute the power from Grid_to_powerwall and remove that from "Self-Power" by solar: # Compute power from Grid to Powerwall
grid_to_powerwall = ((from_grid - home - solar) + ABS((from_grid - home - solar))) / 2
# Compute power from Solar to Powerwall
solar_to_powerwall = to_pw - grid_to_powerwall
# Compute amount of Solar powering House
Solar_SelfPower = solar - solar_to_powerwall - to_grid Using that equation to compute the Solar part of the "Self Power" panel looks like this:
PowerwallThe "From Powerwall" data is correct, showing the amount of energy the Powerwalls are providing to power the house. Actually, there is a condition where this breaks (see below). GridThe "From Grid" data which typically ONLY powers the home, also charges the Powerwall during these events. We need to remove that: The "From Grid" query becomes: # Compute amount of Grid powering House
Grid_SelfPower = from_grid - grid_to_powerwall
ExampleRemaining FlawYES, there is still one major flaw (I'm suspect there are others), and that is, when the Powerwall feeds the Grid (Virtual Power Plant mode). When that occurs, the "From Powerwall" data will be wrong. We need a way to compute that and remove that from the "from_pw" data. |
When a "Storm Watch" event occurs (or if you are allowed to do grid charging of your Powerwalls), the Grafana calculations for "Self-Power" and "Savings" will be wrong. This is due to the way that "from_solar" is computed:
This takes the total solar generation number (from_solar) and subtracts power to the grid (to_grid) and power to the Powerwalls (to_pw). Most of the time this works perfectly, but during events when "grid to Powerwall" occurs, the charging energy is reduced from the solar generation total.
I'm not sure there is an easy way to fix this. Ideally we would be able to decorate the "to_pw" (to Powerwall) with either "from Grid" or "from Solar" to be able to arrive at an accurate calculation.