Notifications
You must be signed in to change notification settings - Fork 0
/
__init__.py
379 lines (340 loc) · 12.6 KB
/
__init__.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
"""Support for Modbus."""
import logging
import threading
from pymodbus.client.sync import ModbusSerialClient, ModbusTcpClient, ModbusUdpClient
from pymodbus.transaction import ModbusRtuFramer
import voluptuous as vol
from homeassistant.components.cover import (
DEVICE_CLASSES_SCHEMA as COVER_DEVICE_CLASSES_SCHEMA,
)
from homeassistant.const import (
ATTR_STATE,
CONF_COVERS,
CONF_DELAY,
CONF_DEVICE_CLASS,
CONF_HOST,
CONF_METHOD,
CONF_NAME,
CONF_PORT,
CONF_SCAN_INTERVAL,
CONF_SLAVE,
CONF_STRUCTURE,
CONF_TIMEOUT,
CONF_TYPE,
EVENT_HOMEASSISTANT_STOP,
)
import homeassistant.helpers.config_validation as cv
from homeassistant.helpers.discovery import load_platform
from .const import (
ATTR_ADDRESS,
ATTR_HUB,
ATTR_UNIT,
ATTR_VALUE,
CALL_TYPE_COIL,
CALL_TYPE_REGISTER_HOLDING,
CALL_TYPE_REGISTER_INPUT,
CONF_BAUDRATE,
CONF_BYTESIZE,
CONF_CLIMATES,
CONF_CURRENT_TEMP,
CONF_CURRENT_TEMP_REGISTER_TYPE,
CONF_DATA_COUNT,
CONF_DATA_TYPE,
CONF_INPUT_TYPE,
CONF_MAX_TEMP,
CONF_MIN_TEMP,
CONF_OFFSET,
CONF_PARITY,
CONF_PRECISION,
CONF_REGISTER,
CONF_SCALE,
CONF_STATE_CLOSED,
CONF_STATE_CLOSING,
CONF_STATE_OPEN,
CONF_STATE_OPENING,
CONF_STATUS_REGISTER,
CONF_STATUS_REGISTER_TYPE,
CONF_STEP,
CONF_STOPBITS,
CONF_TARGET_TEMP,
CONF_UNIT,
DATA_TYPE_CUSTOM,
DATA_TYPE_FLOAT,
DATA_TYPE_INT,
DATA_TYPE_UINT,
DEFAULT_HUB,
DEFAULT_SCAN_INTERVAL,
DEFAULT_SLAVE,
DEFAULT_STRUCTURE_PREFIX,
DEFAULT_TEMP_UNIT,
MODBUS_DOMAIN as DOMAIN,
SERVICE_WRITE_COIL,
SERVICE_WRITE_REGISTER,
)
_LOGGER = logging.getLogger(__name__)
BASE_SCHEMA = vol.Schema({vol.Optional(CONF_NAME, default=DEFAULT_HUB): cv.string})
CLIMATE_SCHEMA = vol.Schema(
{
vol.Required(CONF_CURRENT_TEMP): cv.positive_int,
vol.Required(CONF_NAME): cv.string,
vol.Required(CONF_SLAVE): cv.positive_int,
vol.Required(CONF_TARGET_TEMP): cv.positive_int,
vol.Optional(CONF_DATA_COUNT, default=2): cv.positive_int,
vol.Optional(
CONF_CURRENT_TEMP_REGISTER_TYPE, default=CALL_TYPE_REGISTER_HOLDING
): vol.In([CALL_TYPE_REGISTER_HOLDING, CALL_TYPE_REGISTER_INPUT]),
vol.Optional(CONF_DATA_TYPE, default=DATA_TYPE_FLOAT): vol.In(
[DATA_TYPE_INT, DATA_TYPE_UINT, DATA_TYPE_FLOAT, DATA_TYPE_CUSTOM]
),
vol.Optional(CONF_PRECISION, default=1): cv.positive_int,
vol.Optional(CONF_SCALE, default=1): vol.Coerce(float),
vol.Optional(CONF_SCAN_INTERVAL, default=DEFAULT_SCAN_INTERVAL): vol.All(
cv.time_period, lambda value: value.total_seconds()
),
vol.Optional(CONF_OFFSET, default=0): vol.Coerce(float),
vol.Optional(CONF_MAX_TEMP, default=35): cv.positive_int,
vol.Optional(CONF_MIN_TEMP, default=5): cv.positive_int,
vol.Optional(CONF_STEP, default=0.5): vol.Coerce(float),
vol.Optional(CONF_STRUCTURE, default=DEFAULT_STRUCTURE_PREFIX): cv.string,
vol.Optional(CONF_UNIT, default=DEFAULT_TEMP_UNIT): cv.string,
}
)
COVERS_SCHEMA = vol.All(
cv.has_at_least_one_key(CALL_TYPE_COIL, CONF_REGISTER),
vol.Schema(
{
vol.Required(CONF_NAME): cv.string,
vol.Optional(CONF_SCAN_INTERVAL, default=DEFAULT_SCAN_INTERVAL): vol.All(
cv.time_period, lambda value: value.total_seconds()
),
vol.Optional(CONF_DEVICE_CLASS): COVER_DEVICE_CLASSES_SCHEMA,
vol.Optional(CONF_SLAVE, default=DEFAULT_SLAVE): cv.positive_int,
vol.Optional(CONF_STATE_CLOSED, default=0): cv.positive_int,
vol.Optional(CONF_STATE_CLOSING, default=3): cv.positive_int,
vol.Optional(CONF_STATE_OPEN, default=1): cv.positive_int,
vol.Optional(CONF_STATE_OPENING, default=2): cv.positive_int,
vol.Optional(CONF_STATUS_REGISTER): cv.positive_int,
vol.Optional(
CONF_STATUS_REGISTER_TYPE,
default=CALL_TYPE_REGISTER_HOLDING,
): vol.In([CALL_TYPE_REGISTER_HOLDING, CALL_TYPE_REGISTER_INPUT]),
vol.Exclusive(CALL_TYPE_COIL, CONF_INPUT_TYPE): cv.positive_int,
vol.Exclusive(CONF_REGISTER, CONF_INPUT_TYPE): cv.positive_int,
}
),
)
SERIAL_SCHEMA = BASE_SCHEMA.extend(
{
vol.Required(CONF_BAUDRATE): cv.positive_int,
vol.Required(CONF_BYTESIZE): vol.Any(5, 6, 7, 8),
vol.Required(CONF_METHOD): vol.Any("rtu", "ascii"),
vol.Required(CONF_PORT): cv.string,
vol.Required(CONF_PARITY): vol.Any("E", "O", "N"),
vol.Required(CONF_STOPBITS): vol.Any(1, 2),
vol.Required(CONF_TYPE): "serial",
vol.Optional(CONF_TIMEOUT, default=3): cv.socket_timeout,
vol.Optional(CONF_CLIMATES): vol.All(cv.ensure_list, [CLIMATE_SCHEMA]),
vol.Optional(CONF_COVERS): vol.All(cv.ensure_list, [COVERS_SCHEMA]),
}
)
ETHERNET_SCHEMA = BASE_SCHEMA.extend(
{
vol.Required(CONF_HOST): cv.string,
vol.Required(CONF_PORT): cv.port,
vol.Required(CONF_TYPE): vol.Any("tcp", "udp", "rtuovertcp"),
vol.Optional(CONF_TIMEOUT, default=3): cv.socket_timeout,
vol.Optional(CONF_DELAY, default=0): cv.positive_int,
vol.Optional(CONF_CLIMATES): vol.All(cv.ensure_list, [CLIMATE_SCHEMA]),
vol.Optional(CONF_COVERS): vol.All(cv.ensure_list, [COVERS_SCHEMA]),
}
)
SERVICE_WRITE_REGISTER_SCHEMA = vol.Schema(
{
vol.Optional(ATTR_HUB, default=DEFAULT_HUB): cv.string,
vol.Required(ATTR_UNIT): cv.positive_int,
vol.Required(ATTR_ADDRESS): cv.positive_int,
vol.Required(ATTR_VALUE): vol.Any(
cv.positive_int, vol.All(cv.ensure_list, [cv.positive_int])
),
}
)
SERVICE_WRITE_COIL_SCHEMA = vol.Schema(
{
vol.Optional(ATTR_HUB, default=DEFAULT_HUB): cv.string,
vol.Required(ATTR_UNIT): cv.positive_int,
vol.Required(ATTR_ADDRESS): cv.positive_int,
vol.Required(ATTR_STATE): cv.boolean,
}
)
CONFIG_SCHEMA = vol.Schema(
{
DOMAIN: vol.All(
cv.ensure_list,
[
vol.Any(SERIAL_SCHEMA, ETHERNET_SCHEMA),
],
),
},
extra=vol.ALLOW_EXTRA,
)
def setup(hass, config):
"""Set up Modbus component."""
hass.data[DOMAIN] = hub_collect = {}
for conf_hub in config[DOMAIN]:
hub_collect[conf_hub[CONF_NAME]] = ModbusHub(conf_hub)
# load platforms
for component, conf_key in (
("climate", CONF_CLIMATES),
("cover", CONF_COVERS),
):
if conf_key in conf_hub:
load_platform(hass, component, DOMAIN, conf_hub, config)
def stop_modbus(event):
"""Stop Modbus service."""
for client in hub_collect.values():
client.close()
def write_register(service):
"""Write Modbus registers."""
unit = int(float(service.data[ATTR_UNIT]))
address = int(float(service.data[ATTR_ADDRESS]))
value = service.data[ATTR_VALUE]
client_name = service.data[ATTR_HUB]
if isinstance(value, list):
hub_collect[client_name].write_registers(
unit, address, [int(float(i)) for i in value]
)
else:
hub_collect[client_name].write_register(unit, address, int(float(value)))
def write_coil(service):
"""Write Modbus coil."""
unit = service.data[ATTR_UNIT]
address = service.data[ATTR_ADDRESS]
state = service.data[ATTR_STATE]
client_name = service.data[ATTR_HUB]
hub_collect[client_name].write_coil(unit, address, state)
# do not wait for EVENT_HOMEASSISTANT_START, activate pymodbus now
for client in hub_collect.values():
client.setup()
# register function to gracefully stop modbus
hass.bus.async_listen_once(EVENT_HOMEASSISTANT_STOP, stop_modbus)
# Register services for modbus
hass.services.register(
DOMAIN,
SERVICE_WRITE_REGISTER,
write_register,
schema=SERVICE_WRITE_REGISTER_SCHEMA,
)
hass.services.register(
DOMAIN, SERVICE_WRITE_COIL, write_coil, schema=SERVICE_WRITE_COIL_SCHEMA
)
return True
class ModbusHub:
"""Thread safe wrapper class for pymodbus."""
def __init__(self, client_config):
"""Initialize the Modbus hub."""
# generic configuration
self._client = None
self._lock = threading.Lock()
self._config_name = client_config[CONF_NAME]
self._config_type = client_config[CONF_TYPE]
self._config_port = client_config[CONF_PORT]
self._config_timeout = client_config[CONF_TIMEOUT]
self._config_delay = 0
if self._config_type == "serial":
# serial configuration
self._config_method = client_config[CONF_METHOD]
self._config_baudrate = client_config[CONF_BAUDRATE]
self._config_stopbits = client_config[CONF_STOPBITS]
self._config_bytesize = client_config[CONF_BYTESIZE]
self._config_parity = client_config[CONF_PARITY]
else:
# network configuration
self._config_host = client_config[CONF_HOST]
self._config_delay = client_config[CONF_DELAY]
if self._config_delay > 0:
_LOGGER.warning(
"Parameter delay is accepted but not used in this version"
)
@property
def name(self):
"""Return the name of this hub."""
return self._config_name
def setup(self):
"""Set up pymodbus client."""
if self._config_type == "serial":
self._client = ModbusSerialClient(
method=self._config_method,
port=self._config_port,
baudrate=self._config_baudrate,
stopbits=self._config_stopbits,
bytesize=self._config_bytesize,
parity=self._config_parity,
timeout=self._config_timeout,
retry_on_empty=True,
)
elif self._config_type == "rtuovertcp":
self._client = ModbusTcpClient(
host=self._config_host,
port=self._config_port,
framer=ModbusRtuFramer,
timeout=self._config_timeout,
)
elif self._config_type == "tcp":
self._client = ModbusTcpClient(
host=self._config_host,
port=self._config_port,
timeout=self._config_timeout,
)
elif self._config_type == "udp":
self._client = ModbusUdpClient(
host=self._config_host,
port=self._config_port,
timeout=self._config_timeout,
)
else:
assert False
# Connect device
self.connect()
def close(self):
"""Disconnect client."""
with self._lock:
self._client.close()
def connect(self):
"""Connect client."""
with self._lock:
self._client.connect()
def read_coils(self, unit, address, count):
"""Read coils."""
with self._lock:
kwargs = {"unit": unit} if unit else {}
return self._client.read_coils(address, count, **kwargs)
def read_discrete_inputs(self, unit, address, count):
"""Read discrete inputs."""
with self._lock:
kwargs = {"unit": unit} if unit else {}
return self._client.read_discrete_inputs(address, count, **kwargs)
def read_input_registers(self, unit, address, count):
"""Read input registers."""
with self._lock:
kwargs = {"unit": unit} if unit else {}
return self._client.read_input_registers(address, count, **kwargs)
def read_holding_registers(self, unit, address, count):
"""Read holding registers."""
with self._lock:
kwargs = {"unit": unit} if unit else {}
return self._client.read_holding_registers(address, count, **kwargs)
def write_coil(self, unit, address, value):
"""Write coil."""
with self._lock:
kwargs = {"unit": unit} if unit else {}
self._client.write_coil(address, value, **kwargs)
def write_register(self, unit, address, value):
"""Write register."""
with self._lock:
kwargs = {"unit": unit} if unit else {}
self._client.write_register(address, value, **kwargs)
def write_registers(self, unit, address, values):
"""Write registers."""
with self._lock:
kwargs = {"unit": unit} if unit else {}
self._client.write_registers(address, values, **kwargs)