The eCRNow App can be configured for a healthcare setting following the instructions in the document
This section describes configuration properties typically performed for all health care settings and are not something that would be changed through the UI or APIs.
By default the eCRNow App uses the postgresql database, however it can be changed using the below properties to suit your environment.
jdbc.driverClassName=org.postgresql.Driver jdbc.url=jdbc:postgresql://localhost:5432/postgres hibernate.dialect=org.hibernate.dialect.PostgreSQL95Dialect hibernate.show_sql=false hibernate.format_sql=false hibernate.hbm2ddl.auto=update
Use the property below to change the default port of the app from 8081 to another port.
server.port=8081
Use the property below to change the log file location.
logging.file.name=//users//nbashyam//Downloads//ecrNow.log
Use the property below to configure the schema validation.
xsd.schemas.location=//users//nbashyam//Downloads//schemas//CDA_SDTC.xsd
Use the property below to configure the schematron validation.
schematron.file.location=//users//nbashyam//Downloads//CDAR2_IG_PHCASERPT_R2_STU1.1_SCHEMATRON.sch
There are many instances where eCRNow may call a RESTful endpoint hosted by the EHR vendor to hand-off an eICR for submission or for handling a Reportability Response. In these cases the EHR vendor may require a specific authorization token to invoke the API. In order to embed the required authorization token, the mechanisms identified in security configuration should be followed.
Similarly there are instructions in the security configuration section on how to protect the eCRNow API endpoints with appropriate security tokens from your authorization server.
There are instances where a timer execution may fail and it needs to be retried. The number of retries can be configured using the property
timer.retries=2
If the timers fail repeatedly, the timer will be removed from execution after the retry counts are exhausted.
In order to process more patients in container based on timers, the following property can be adjusted. In this case, a default of 10 parallel patients can be processed by the expiring timers within the container.
db-scheduler.threads=10
2.8 Specifying the directory to save generated artifacts such as eICRs, TriggerQuery and Loading Query JSON files for debugging
This is controlled by the bsa.output.directory property.
You also have to set the save.debug.files=true if you want the files to be saved. If this is set to false, the files would not be saved.
Sometimes the EHR server may be busy and cannot service requests from the eCRNow App. In order to avoid failures because the server is busy you can enable throttling of the eCRNow App. Follow the Throttling instructions to configure the app.
By default, the eCRNow app executes default queries present in the ERSD files. The default queries are based on US Core 3.1.1 and may not be the most efficient way of getting data out from the EHRs.
For e.g the default query to retrieve Conditions for a Patient is /Condition?subject=Patient/123 which retrieves all Conditions. However if you want to configure a query that removes the inactive or resolved conditions you can do something like :
/Condition?patient=Patient/{{context.patientId}}&clinical-status=http://terminology.hl7.org/CodeSystem/condition-clinical|active
Read custom query configuration to further understand how to configure custom queries.
EHRs are used by Providers as part of the care delivery operations and there may be large amount of load on the EHRs during the day time and there may be a desire to reduce the load during the working hours or peak usage hours. In these cases, it is beneficial if the eCRNow App can be configured to only process patients whose data has to be reported immediately and delay the processing of the other patients to off hours (non peak hours). This kind of configuration can be achieved by the OffHour Configuration.
EHR implementers can configure the EHR Product name and version that the ecrNowApp interfaces with using the two application properties
- ehr.product.name="EHR Product Name: for e.g., AthenaOne, AthenaPractice, CernerMillenium"
- ehr.product.version="EHR ProductVersion"
If these are present in the application.properties, then an author participant is added to the CDA eICR to convey this information. If it is not present, the author is not added.
eCRNow App implementers can configure the their name and software version used for the integration. This is useful for system integrators and other vendors who are working on behalf of the healthcare organization and want to distinguish their eICRs from other vendors and/or other healthcare organizations. These are configured using two application properties namely
- ecrnow.implementer.name="Implementer Organization Name: for e.g., Athena, Oracle"
- ecrnow.implementer.version=3.1.5
By default the version should be set to the App Release version. If these are present in the application.properties, then an author participant is added to the CDA eICR to convey this information. If it is not present, the author is not added.
There are times during startup when the application loads ERSD/KARs, CQL libraries etc, and there is spike in memory and CPU usage. When the application is booting up, it is better to delay launching patients until the application has completely booted up. To control the timing there is an application property that specifies the number of seconds to wait before accepting launchPatient requests.
- startup.timedelay=10