Corrosion Modeling and Analysis Applications

Serves as a repository for multiple applications related to corrosion modeling and analysis of experimental data.


1. Experimental Data Analysis

This MATLAB GUI application and supporting datafile extraction functions (found in the experimental-data-analysis folder) were developed to support the analysis of raw datafiles obtained from potentiostats as the output from several common corrosion experiments.

Note: Version 2.0 of the code has been successfully tested on datafiles from the following types of Gamry ®️ experiments:

Experiment Type Gamry Label
Open-circuit potential measurement CORPOT
Cyclic polarization measurement CYCPOL
Potentiodynamic polarization measurement POTDYN
Potentiostatic electrochemical impedance spectroscopy EISPOT

The main application depends on the following functions that handle analysis of the Gamry ®️ datafiles:

  • AnalyzeGamryCORPOTData.m
  • AnalyzeGamryCYCPOLData_2.m
  • AnalyzeGamryEISData.m
  • AnalyzeGamryPOTDYNData.m

Installation

The application is installed by clicking on the “Install App” button on the MATLAB Apps tab in the command window, as shown in Fig. 1:

Figure1

Figure 1. Install a MATLAB App.

Navigate to the folder where the app installer is located, and it will automatically be added to the apps dropdown list, under the My Apps section in the command window, as shown in Fig. 2.

Figure2

Figure 2. Location for the newly-installed MATLAB App.

App Functionality

Interactions with the app GUI generally flow from upper-left to lower-right of the Interaction Panel. A general sequence of steps is shown in Figure 3 and described below.

Figure3

Figure 3. Numbered sequence for interacting with the GUI to load and plot raw datafiles.

  1. Click on ‘File’, which expands a toolstrip showing ‘New’ – which clears all variables, ‘Close’ – which closes the app, and ‘Select Data Directory’.
  2. Clicking on ‘Select Data Directory’ opens a folder browser dialog box. Navigate to the folder containing the raw datafiles of interest.
    1. Note: The app currently does not search subfolders, so all data needs to be in the selected folder.
  3. Once a directory has been selected, clicking on the down arrow opens a drop-down list, as shown below, to select the type of experimental data to be plotted.
    1. The app will scan the selected directory for experimental data files that match the type selected. Any matching files that are found are added to the text box in step 4.
Figure3
  1. If multiple files are present in the text box, clicking the filename highlights its name and adds it to the list of files to be plotted. The order the files are clicked is the order they are added to the plot.
  2. Enter descriptive text into the ‘Legend Info’ text box for each plotted datafile, separating each description by a comma. These will label the symbols plotting the data in the following step.
  3. Clicking the ‘Plot’ button displays the data on one or two axes, depending on the type of data, in the Plot Panel.
  4. Clicking on the ‘Save Plot’ button opens a ‘Save File’ dialog that allows the filename to be entered and a selection of image types to save the file. It also automatically generates CSV files for each data file shown in the plot.

Principal Supporting Functions

The experimental datafile analysis supporting functions all follow the same general procedure, so only one is described below.

Analyze Gamry POTDYN Data Function

This function loads a Gamry DTA file obtained from a potentiodynamic polarization experiment. It extracts the open-circuit potential data and the polarization data from their respective areas of the file. It will also extract exposed area value from AREA entry in the file. The area value and the OCP and polarization data are returned from the function as a variable and a MATLAB table, respectively.


2. EIS Data Analysis

This project (found in the eis-analysis folder) was developed to facilitate the analysis of electrochemical impedance spectroscopy (EIS) data obtained from potentiostatic EIS experiments.

Note: The code has not been tested to determine if it works with galvanostatic EIS data.

The main function depends on files contained in the following sub-directories:

  • "Circuit Element Models"
  • "Equivalent Circuit Models"
  • "Fitting Algorithms"

Data files are expected to be found in a "Data" directory. Fit results are stored in a "Fit" directory. All functions and classes are written in MATLAB®.

Main Function

This function serves as the entry point for the project to analyze and fit EIS data. It can be customized depending on the physical system the EIS data was collected from, but it needs to perform the following actions:

  • Clear the command window, all figures, and all variables from the workspce.
  • Add the paths to the sub-directories containing the functions for the equivalent circuit impedance calculations and other supporting classes.
  • Create a cell array of data filenames
  • Iterate through the filenames to extract the impedance data.
  • Instantiate an instance of the eisFitController class for each datafile, pass the data to the constructor as well as the equivalent circuit type, and initial guess of the fit parameter values

Definitions for the variables in the Main function are provided below:

  • datafilenames = cell arrray containinng filenames of the raw Gamry data files
  • selectedEquivalentCircuit = character vector specifying the equivalent circuit to be used to fit the data. Available circuits are listed in the following sub-section
  • vectorOfInitialParameterEstimates = array of values for the initial parameter estimates
  • legendString = character array of the descriptions of the data to be plotted on the output plots

Available Equivalent Circuits: Use Table 1 to specify the equivalent circuit impedance function to use in the fitting routine. In the provided code example, it can be seen that ‘ModifiedRandles’ was the circuit that was selected.

Table 1. Available equivalent circuit impedance functions for fitting to EIS data. The 2nd column lists the value for the selectedEquivalentCircuit class instance that is created for each datafile. The 3rd column lists the number of initial parameter values that must be passed to the fitting function.

Circuit Name Name to pass to the EISFitController Instance Number of fit parameters needed in vector
Undamaged Coating UndamagedCoating 3
Modified Undamaged Coating ModifiedUndamagedCoating 4
Randles Randles 5
Modified Randles ModifiedRandles 6
Nested Randles Coating Defect NestedRandlesCoatingDefect 5
Rapid Electrochemical Assessment of Paint (REAP) REAP 6
Modified REAP ModifiedREAP 7

Examples of the output text with the fit parameter values and a Bode plot of the EIS data and fit are shown in Figure 4a and Figure 4b, respectively.

a b
Figure1a Figure1b

Figure 4. a. Example output from the fitting routine. b. Bode plot of the impedance modulus vs potential oscillation frequency and the phase of the response vs the potential oscillation frequency. Open symbols indicate data, the line indicates the fit.

Principal Supporting Functions and Classes

eisFitController

This function calls the specified equivalent circuit model that will fit the data and passes the initial parameter set estimate to the fitting function. It also establishes the constratint limts on the fit parameters for the simplex algorithm and calls the fitting function. Lastly, it stores the results of the fit in output files. Fit parameter values are output to the command window.

Function inputs

  • T = instance of eisdata class
  • fType = name of the equivalent circuit model to be used to analyze the data
  • beta0 = array of values for the initial guess for the fit
  • fitDirectory = directory where fit results are stored
  • legendForPlotString = string of descriptions for the data on the plot

Function outputs

  • Files with fit values and list of fit parameters to the command window

3. Polarization Curve Modeling

Using this code (found in the polarization-curve-modeling folder), polarization curves can be obtained across a range of temperatures, concentrations, pH values, and electrolyte flow velocities. Note, though, that the simplified nature of the polarization curves obtained from this modeling approach arises becuase these are intended to serve as boundary conditions for FEM of complex parts and components exposed to corrosive environments. The BCs on the electrode surfaces in those calculations are restricted to single-valued functions. Thus, observed polarization behavior that results in active-passive transitions, for example, will not be captured by these models.

Main Function

Unlike the classes that are described in the following section, the main function is not unique. It serves as the entry point to the code for modeling a polarization curve. Whatever this function is named, however, it must accomplish the following actions:

  • Clear the command window, all figures, and all variables from the workspace.
  • Instantiate an instance of the Constants class.
  • Define the potential region of interest
  • Define the various environmental conditions for generating the polarization curves
  • Iterate through the environmental conditions to construct instances of the PolarizationCurveModel class and call the plotting function for the defined polarization curves.

Two examples of the polarization curves for the same material but with different environmental conditions that can be generated are shown in Figure 5.

a b
Figure5a Figure5b
c d
Figure5c Figure5d

Figure 5. a. Modeled polarization curve for a 316 stainless steel in 0.02 M NaCl solution at 5oC, pH = 3, and a flow velocity of 5 m/s. b. Modeled polarization curve for a 316 stainless steel in 0.6 M NaCl solution at 25oC, pH = 7, and a flow velocity of 5 m/s. c. Modeled polarization curve for a CuNi 70-30 alloy in 0.02 M NaCl solution at 5oC, pH = 3, and a flow velocity of 5 m/s. d. Modeled polarization curve for a CuNi 70-30 alloy in 0.6 M NaCl solution at 25oC, pH = 7, and a flow velocity of 5 m/s.

Principal Sub-Functions and Classes

The principal supporting classes and sub-functions that are used in the model include the following:

  • Constants - a class that defines a number of conversion values for converting units as well as a number of physical parameters for electrochemical calculations.
  • PolarizationCurveModel - a class that creates an object to calculate and plot a polarization curve.

Constants and Conversion Factors

This class contains variables storing physical constant values for use in electrochemical calculations.

Polarization Curve Class

This class serves as the template to create an object that can calculate and plot a polarization curve. Alloys specifically included in this version of the code:

  • HY 80
  • HY 100
  • SS 316
  • Ti
  • CuNi (Wrought, 70-30 alloy)
  • I625

Note This version of the code contains estimates for reaction properties for the alloys specified above. If additional alloys are to be considered, their model reaction properties must be included in the Polarization Curve class, or this version of the code must be changed so the values can be obtained elsewhere (see Roadmap).


3. Pipe Spool Galvanic Couple Modeling

Physics-based and response surface models (found in the pipe-spool-model folder) are used to calculate the galvanic interactions between 2 pipe spools composed of different materials and exposed to a user-specified electrolyte, as shown in Figure 6.

Figure6

Figure 6. Galvanic couple between pipe spools of different materials.

The pipe spools are simplified to 2-dimensional interactions by assuming axial and radial symmetry. The polarization curves that are used for the electrode boundary conditions in this work were calculated using the functions and procedures developed in the "Polarization Curve Modeling" project.

Main Function

This example function serves as the entry point to the code for modeling the galvanic interaction between two pipe spools. It must accomplish the following actions:

  • Clear the command window, all figures, and all variables from the workspace.
  • Ensure the code can find supporting classes in the respective sub-folders
  • Provide paths to the raw data and any other model results (if needed)
  • Instantiate a PipeLoopModel object
  • Define the properties of the pipe spools and the computational cell properties
  • Define the various environmental conditions for generating the polarization curves
  • Instantiate a GalvanicCorrosion object
  • Iterate through the environmental conditions to define and plot the defined polarization curves.

Examples of the polarization curve calculations for the different materials and the potential distribution are shown in Figure 7a and Figure 7b, respectively.

a b
Figure7a Figure7b

Figure 7. a. Individual polarization curves and combined galvanic corrosion response for the modeled I625 and wrought CuNi pipe spools. b. Comparison of the measured and modeled potential distributions for a pipe spool galvanic couple between I625 and wrought CuNi in flowing seawater.

Principal Sub-Functions and Classes

The principal supporting classes and sub-functions that are used in the model include the following:

  • PipeLoopModel - a class that contains model predictions and experimental results for comparisons.
  • galvanicCorrosion - a class that contains functions for performing the potential distribution calculation for the galvanic couple between the pipe spools.

Pipe Loop Model

This class serves as a holding center for gathering experimental data and model outcomes from files.

Galvanic Corrosion Simulation

This class defines the computational cell and contains the static functions that perform the Symmetric Over-Relaxation (SOR) calculation to obtain the potential distribution by solving the Laplace equation in 2 dimensions.


5. Corrosion Model 6

This application provides a shortcut for basic corrosion insight for a variety of galvanic couples between different metals, alloys, and materials.

Background

The origin of project grew out of the desire to provide useful corrosion information contained in unclassified, unrestricted distribution, standards that still seemed to be difficult to find if you didn't know what you were looking for. For example, the basis of this project is:

MIL-STD-889C Dissimilar Metals

It was originally published in 1969 and subsequently updated in 1976 and in 2016 with a couple of minor changes and revisions in between. I have not been able to track down a copy of the original standard but the 1976 and 2016 versions are available here.

Project Goals

This project aims to achieve the following goals:

  • Provide the user with a list of different materials that can be selected to be combined into a galvanic couple
  • Provide an estimate of the respective, isolated, corrosion potentials for the two materials (currently only from seawater exposure)
  • Provide an estimate of the corrosion potential difference between the materials. This provides an estimate of the overpotential available to drive corrosion, though no kinetics information is provided.

  • Provide an estimate, obtained from Table 1 (see image to the right) on pg. 6 of MIL-STD-889C, of the relative compatibility of the different materials in three different environments:
    1. Marine atmopshere
    2. Seawater
    3. Industrial atmosphere
  • Summarize the corrosion prevention strategies for different classes of materials as contained in Appendix A.
  • Provide Windows, Android, and iOS versions of the app

Code

This project was written in C# and XAML using Microsoft Visual Studio. The data file used for the electrochemical potentials and material-types is written in XML. The data file used to pull the corrosion prevention recommendations is also written in XML. The data file used to summarize the Table I recommendations is a CSV file.

Universal Windows Platform (UWP) App

The current version of the app is available as a free download here. Or it can be built in Visual Studio from the source files.