- ZigPC migrated to Simplicity SDK v2024.6.0 with alpha quality.
- Reference platform updated to Bookworm 64-bit based Raspberry Pi OS.
- Migrated to Zigbee EmberZNet SDK v8.0.0.0
- Added the support (alpha quality) for below clusters- 'Basic', 'Metering', 'ElectricalMeasurement', 'PowerConfiguration', 'WindowCovering', 'TemperatureMeasurement'
- Fixed mqtt specific argument parsing.
- Added options to configure the Zigbee network parameters on startup
- JSON handling bugfixes
- Network management improvements
- Ease of use updates for adding new or custom clusters
- Added a bugfix addressing binding issues
- Enabled the minimum required attributes for ApplicationMonitoring.
- Add the possiblity of enabling emberCLI at compile time. Use command embercli in Zigpc CLI to send command to the z3gateway cli.
- Added CLI option to configure attribute polling rate, can be set in uic.cfg under zigpc.attr_polling_rate_ms.
- Added support for bindings through MQTT.
- Reference platform updated to Bullseye 64-bit based Raspberry Pi OS.
- Migrated to Gecko SDK version to v4.2.0.
- General network improvements.
- JSON Parsing bugfix
- Attribute polling bugfix
- Network management improvements allowing parallel device joins and discovery
- Added CLI option to configure OTA file folder destination
- Added CLI option to poll attributes only and disable report configuration
- Added zigbeed/multiprotocol integration
- Bugfix for zigpc failing to start when the OTA file folder is not found
- Update zigpc Linux permissions
- Removed zigpc service auto-start to allow user to prevent conflicts with multiprotocol integration
- More general bugfix for crashing on mal-formed JSON
- Migrated to GeckoSDK 4.1
- The NCP firmware update component to enable upgrading the NCP firmware using the zigbee protocol controller
- Fixed a bug where the zigbee protocol controller would crash on malformed JSON
- Debian Installer also configures ZigPC to run as a system service
- Ability to get ZigPC specific diagnostic information (uptime, CPU use, memory use, Zigbee stack counters) from the host and the coordinator
- ZAP and SLC_CLI has been integrated as project dependencies for Zigbee host library generation
- Attribute polling if report configuration fails
- Publishing GeneratedCommands sent from Zigbee devices as responses or as unsolicited events
- Migrate Zigbee-Host library (EmberZNet-based) from Appbuilder project (GeckoSDK 3.1) to SLC project (GeckoSDK 4.0). See Zigbee Host Library Readme for more details. NOTE: In order to listen to new ZCL cluster messages, the SLC project configuration should be changed in addition to the ZAP dotdot helpers
- ZigPC datastore file key has been changed from --datastore.file to --zigpc.datastore_file
- Default datastore file has been changed from /var/lib/uic/database.db to /var/lib/uic/zigpc.db
If you used the default configuration, keep your previous database by running
mv /var/lib/uic/database.db /var/lib/uic/zigpc.db
- Use of EmafDeviceTablePlugin in Zigbee-Host library to manage device discovery; This is now performed within ZigPC
- Persisted information cleanup on device leaving the network
- JSON payloads accepted for commands and attributes to be UCL compliant
- Add persistence of Zigbee device discovery information to allow servicing devices after ZigPC reboots
- Use of NCP address-table to manage EUI64 to NodeId mappings
- Updates to network management
- Improvements in Zigbee Host EZSP message performance
- Merge ZigPC node state and ucl handling components
- Reduce dependence on device table plugin, use address table
- Improved ZCL frame error handling and empty string bug fix
- Node unretain messages bugfix
- Empty group name bugfix
- Added polling for unreportable attributes
- Build issues
- Implementation of Unify specification 1.0
- Sleepy end device support
- Support for performing Over The Air update(OTA) of Zigbee devices
- Multicast/Groups support
- Zigbee Trust Center support
- Zigbee device provisioning using Z3 Install Codes
- Attribute reporting configuration on supported clusters
- UCL ForceReadAttribute support
- UCL to ZCL command + attribute mappings
- (0x0003) Identify
- (0x0004) Groups
- (0x0006) OnOff
- (0x0008) Level
- (0x0101) DoorLock
- (0x0201) Thermostat
- (0x0300) ColorControl
- (0x0406) OccupancySensing
- Zigbee Host-NCP EZSP-UART Support
- Various bug fixes
- Documentation updates
Known Issue | Workaround |
---|---|
If connection to the MQTT broker is lost, ZigPC does not re-subscribe to topics | Restart ZigPC. |
User may experience outdated devices that are still listed from cached data in the browser | A fresh browser session can remove outdated devices. |
Network management state is not published correctly if UPVL is started after ZigPC | Start UPVL before ZigPC. |
The UPVL becomes unresponsive to MQTT messages and will miss MQTT messages published to "ucl/SmartStart/List/Update" | Restart UPVL. |
Including a node using the SmartStart list is only effective for 18 hours | Ensure that a node is added within 18 hours of being put in the SmartStart List. |
When performing network-steering, the device can either fail node addition or node interview partially. | In the device's EmberCLI, enter the commands network leave and keys clear then retry. |
When excluding devices, the protocol UNID is not removed from the node's SmartStart entry. This will cause the ZigPC to refuse to re-include the node. | Clear the ZigPC UNID from the SmartStart entry using the Dev UI. |
ZigPC only supports "Remove" and "Idle" PC state change requests via the Node List view in DevUI. "Add" and "Reset" options are not supported. | To add nodes to the Zigbee network, using the Smartstart DSK process outlined in the readme. |
ZigPC can fail at initialization if the NCP image is based on GSDK 4.1 without ADDRESS_TABLE being set to 32 | Set macro EMBER_ADDRESS_TABLE_SIZE=32 in NCP studio project before building NCP image. |
ZigPC can fail at initialization if the NCP image is based on a different version of the GeckoSDK than ZigPC | Update the NCP image to the same GeckoSDK version as the one used to compile the ZigPC. |
ZigPC sends the default response to a sleepy check-in command instead of the expected acknowledge message | Disable the poll control cluster when managing sleepy devices to use the default behaviour. |
ZigPC may take longer than expected to perform an OTA upgrade | Minimize the size of the image and leave sufficient time to update end devices. |
When running in a multiprotocol setup, permission issues may cause the setup to fail | Use 'sudo' when running both ZigPC and the Zigbeed applications to ensure compatibility |
Vendor | Name | Device Type | Working | Notes |
---|---|---|---|---|
Silabs | xG12 or xG21 radio (NCP w/ EZSP-UART) | Yes | ||
Silabs | xG12 or xG21 radio | Z3Light | Yes | |
Silabs | xG12 or xG21 radio | Z3Switch | Yes | |
Silabs | xG12 or xG21 radio | Z3Thermostat | Yes | |
Silabs | xG12 or xG21 radio | Z3DoorLock | Yes |
NOTE the ZigPC is at this point not certifiable