Skip to content

Icinga / Nagios check plugin to verify HPE controllers an SSD disks are not affected by certain vulnerabilities

License

Notifications You must be signed in to change notification settings

NETWAYS/check_hp_firmware

Repository files navigation

check_hp_firmware

Monitoring check plugin to verify HPE controllers an SSD disks are not affected by certain vulnerabilities.

Note: This plugin was initially named check_hp_disk_firmware.

Current Limitations:

  • No SNMPv3 support is implemented

HPE Controllers

HPE Smart Array SR Gen10 Controller Firmware Version 2.65 (or later) provided in the (HPE document a00097210) is required to prevent a potential data inconsistency on select RAID configurations with Smart Array Gen10 Firmware Version 1.98 through 2.62, based on the following scenarios. HPE strongly recommends performing this upgrade at the customer's earliest opportunity per the "Action Required" in the table located in the Resolution section. Neglecting to perform the recommended resolution could result in potential subsequent errors and potential data inconsistency.

The check will alert you with a CRITICAL when the firmware is in the affected range with:

  • if you have RAID 1/10/ADM - update immediately!
  • if you have RAID 5/6/50/60 - update immediately!

And it will add a short note when firmware older than affected or firmware has been updated. At the moment the plugin does not verify configured logical drives, but we believe you should update in any case.

HPE SSD SAS disks

HPE SAS Solid State Drives - Critical Firmware Upgrade Required for Certain HPE SAS Solid State Drive Models to Prevent Drive Failure at 32,768 or 40,000 Hours of Operation

The check will raise a CRITICAL when the drive needs to be updated with the note affected by FW bug, and when the drive is patched with firmware update applied.

HPE Integrated Lights-Out

The check will raise a WARNING when the Integrated Lights-Out needs to be updated. Below you will find a list with the least version of each Integrated Lights-Out version:

  • HPE iLO 6 v1.56 or later
  • HPE iLO 5 v3.01 or later
  • HPE iLO 4 v2.82 or later

IMPORTANT: Always read the latest HPE Security Bulletins. https://support.hpe.com/connect/s/securitybulletinlibrary

The plugin and its documentation is a best effort to find and detect affected hardware. There is no warranty, see the license.

Usage

Arguments:

-H, --hostname string        SNMP host (default "localhost")
-c, --community string       SNMP community (default "public")
-P, --protocol string        SNMP protocol (default "2c")
    --timeout int            SNMP timeout in seconds (default 15)
    --snmpwalk-file string   Read output from snmpwalk
-e, --ilo-exit-state int     Exit with specified code if iLO requires patch (default 1)
-I, --ignore-ilo-version     Don't check the ILO version
-D, --ignore-drives          Don't check the drive firmware
-C, --ignore-controller      Don't check the controller firmware
-4, --ipv4                   Use IPv4
-6, --ipv6                   Use IPv6
-V, --version                Show version
    --debug                  Enable debug output

Simply run the command:

check_hp_firmware -H localhost -c public

Installation

This is a Golang project, either download the binary from the releases:

https://github.com/NETWAYS/check_hp_firmware/releases

Also see the included CheckCommand for Icinga 2.

You can download or build the project locally with go:

git clone https://github.com/NETWAYS/check_hp_firmware
cd check_hp_firmware/
make build

Example

OK - All 2 controllers and 33 drives seem fine
[OK] Integrated Lights-Out 5 revision 2.18 - version newer than affected
[OK] controller (0) model=p816i-a serial=XXX firmware=1.65 - firmware older than affected
[OK] controller (4) model=p408e-p serial=XXX firmware=1.65 - firmware older than affected
[OK] (0.9 ) model=MO003200JWFWR serial=XXX firmware=HPD2 hours=8086
[OK] (0.11) model=EK000400GWEPE serial=XXX firmware=HPG0 hours=8086
[OK] (0.14) model=MO003200JWFWR serial=XXX firmware=HPD2 hours=8086
[OK] (4.0 ) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.31) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.50) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.51) model=MO003200JWFWR serial=XXX firmware=HPD2 hours=7568
[OK] (4.52) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.78) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied
[OK] (4.81) model=MO3200JFFCL serial=XXX firmware=HPD8 hours=7568 - firmware update applied

Contribute

If you find bugs or want to add features, please open an issue or pull-request on GitHub.

You can help with problems by supplying the output of snmpwalk for the system you experience problems with:

$ snmpwalk -c public -v2c -On HOST 1.3.6.1.4.1.232

Please make sure to either censor the output of any private information, or send an e-mail to support@netways.de, so we can provide you with a secure upload link, that won't be shared with public.

Technical Details

Supported hardware is split into modules: hp/cntlr hp/drive hp/ilo

Known models and affected firmware is documented in: hp/cntlr/firmware_data.go hp/phy_drv/firmware_data.go hp/ilo/firmware_data.go

This data can be easily enhanced in the future. Make sure to document source documents and versions as well, and check the accompanying firmware and status functions.

The check reads the cpqDaCntlrTable and cpqDaPhyDrvTable tables from SNMP, which should be available over the IPMI agent or the locally installed HP tools, hooked into the SNMP daemon of the operating system.

License

Copyright (C) 2020 NETWAYS info@netways.de

Copyright (C) 2020 Markus Frosch markus.frosch@netways.de

This program is free software; you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation; either version 2 of the License, or (at your option) any later version.

This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.

You should have received a copy of the GNU General Public License along with this program; if not, write to the Free Software Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA.

About

Icinga / Nagios check plugin to verify HPE controllers an SSD disks are not affected by certain vulnerabilities

Topics

Resources

License

Stars

Watchers

Forks

Packages

No packages published