Notifications
You must be signed in to change notification settings - Fork 0
/
viessmann.py
executable file
·190 lines (170 loc) · 7.28 KB
/
viessmann.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
#!/usr/bin/python3
#
# Script to get data from Viessmann API Server and store it in InfluxDB and/or send it to Domoticz (via MQTT)
#
# Requires:
# 1. Viessmann developer's portal access (to get API key)
# 2. Boiler gateway (wifi module) SN, device ID, boiler SN
# 3. Access refresh code - to be obtained only via http browser
# 4. Refresh token (use get_refresh_token.sh to obtain)
# In order to obtain required data - please read manual: https://developer.viessmann.com/en/doc/getting-started
#
# Author: Michalux
# Version: 3.0
#
import time
import configparser
import urllib3
from urllib.parse import urlencode
import json
import os.path
import sys
import datetime
from datetime import datetime
from influxdb import InfluxDBClient
import paho.mqtt.client as paho
# Refresh access token
def Refresh_Token(clid, reftkn):
data = {
'grant_type': 'refresh_token',
'client_id': clid,
'refresh_token': reftkn
}
encoded_data = urlencode(data)
header.add("Content-Type", "application/x-www-form-urlencoded")
URL="https://iam.viessmann.com/idp/v2/token?"
token_resp = http.request('POST', URL+encoded_data, headers=header)
header.discard("Content-Type")
tokend = json.loads(token_resp.data)
try:
new_token = tokend["access_token"]
except:
print("Problem getting new token:")
print(json.dumps(tokend, indent=4, sort_keys=False, ensure_ascii=False))
sys.exit(1)
return new_token
# Prepare data to write do InfluxDB
def PrepareInfluxData(IfData, fieldname, fieldvalue):
IfData[0]["fields"][fieldname] = float(fieldvalue)
return IfData
def Write2InfluxDB(IfData):
ifclient.write_points(IfData)
def PrepareDomoticzData(DData, idx, svalue):
if isinstance(svalue, str):
DData.append('{ "idx": '+str(idx)+', "svalue": '+ svalue +' }')
else:
DData.append('{ "idx": '+str(idx)+', "svalue": "'+ str(svalue) +'" }')
return DData
os.chdir(os.path.dirname(sys.argv[0]))
# CONFIG
configParser = configparser.RawConfigParser()
configFilePath = r'./config.cfg'
configParser.read(configFilePath)
INSTID=configParser.get('Viessmann', 'Installation_ID')
GWSN=configParser.get('Viessmann', 'Gateway_SN')
DEVICEID=configParser.get('Viessmann', 'Device_ID')
BOILERSN=configParser.get('Viessmann', 'Boiler_SN')
CLIENT_ID=configParser.get('Viessmann', 'Client_ID')
REFRESH_TOKEN=configParser.get('Viessmann', 'Refresh_Token')
INFLUXDB = configParser.get("InfluxDB", "influxdb")
IFHOST = configParser.get("InfluxDB", "influxdb_host")
IFPORT = configParser.get("InfluxDB", "influxdb_port")
IFUSER = configParser.get("InfluxDB", "influxdb_user")
IFPASS = configParser.get("InfluxDB", "influxdb_password")
IFDB = configParser.get("InfluxDB", "influxdb_dbname")
verbose = configParser.get("General", "verbose")
termout = configParser.get("General", "terminal_output")
mqtt=int(configParser.get('MQTT', 'mqtt'))
mqtt_server=configParser.get('MQTT', 'mqtt_server')
mqtt_port=int(configParser.get('MQTT', 'mqtt_port'))
mqtt_topic=configParser.get('MQTT', 'mqtt_topic')
mqtt_username=configParser.get('MQTT', 'mqtt_username')
mqtt_passwd=configParser.get('MQTT', 'mqtt_passwd')
mqtt_tls=configParser.get('MQTT', 'mqtt_tls')
mqtt_tls_insecure=configParser.get('MQTT', 'mqtt_tls_insecure')
mqtt_tls_ver=int(configParser.get('MQTT', 'mqtt_tls_version'))
mqtt_cacert=configParser.get('MQTT', 'mqtt_cacert')
DomoticzData=[]
# Get parameter's definitions to monitor
with open("./params.json") as paramfile:
params=json.loads(paramfile.read())
# Initialise InfluxDB support
if INFLUXDB == "1":
timestamputc = str(datetime.utcnow().strftime("%Y-%m-%d %H:%M:%S"))
ifclient = InfluxDBClient(IFHOST, IFPORT, IFUSER, IFPASS, IFDB)
InfluxData = [{"measurement": "BoilerData", "time": timestamputc, "fields": {}}]
# Initialise HTTP Manager
http = urllib3.PoolManager()
header = urllib3._collections.HTTPHeaderDict()
TIMESTAMP = time.time()
if os.path.isfile('token.json') and os.path.getsize('token.json')>2000: # Check if token file exists and is big enough
with open('token.json') as token_file:
token_data = json.load(token_file)
TOKEN_TIMESTAMP = token_data["Timestamp"]
TOKEN = token_data["Token"]
token_file.close()
else:
TOKEN_TIMESTAMP=TIMESTAMP-3700 # Enforce refreshed token generation (token lifetime = 3600s)
if (TOKEN_TIMESTAMP+3500) < TIMESTAMP:
if verbose=="1":
print("** Old token has expired, requesting a new one **")
TOKEN = Refresh_Token(CLIENT_ID, REFRESH_TOKEN) # Get new, refreshed token
tdata = {
"Timestamp" : TIMESTAMP,
"Token": TOKEN
}
with open('token.json', 'w') as token_file:
json.dump(tdata, token_file) # Write new, refreshed token to a file
token_file.close()
# Get data from Viessmann API Server
header.add("Authorization", "Bearer "+TOKEN)
URL='https://api.viessmann.com/iot/v1/equipment/installations/'+INSTID+'/gateways/'+GWSN+'/devices/'+DEVICEID+'/features/'
apiresponse = http.request('GET', URL, headers=header)
response = json.loads(apiresponse.data)
if "viErrorId" in response:
print("** Error getting boiler data: **")
print(json.dumps(response, indent=4, sort_keys=False, ensure_ascii=False))
sys.exit(1)
if verbose=="1":
print("** Viessmann API server response: **")
print(json.dumps(response, indent=4, sort_keys=False, ensure_ascii=False))
# Parse Viessmann response
for visdata in response["data"]:
for param in params:
if params[param]["Feature"] == visdata["feature"]:
if isinstance(visdata["properties"][params[param]["Key"]]["value"], list):
params[param]["Value"] = visdata["properties"][params[param]["Key"]]["value"][0]
if termout=="1":
print(params[param]["Name"]+":",params[param]["Value"], params[param]["Unit"])
else:
params[param]["Value"] = visdata["properties"][params[param]["Key"]]["value"]
if termout=="1":
print(params[param]["Name"]+":",params[param]["Value"], params[param]["Unit"])
if (mqtt==1 and params[param]["DomoticzIdx"]!=0):
PrepareDomoticzData(DomoticzData, params[param]["DomoticzIdx"], params[param]["Value"])
if INFLUXDB=="1":
PrepareInfluxData(InfluxData, param, params[param]["Value"])
# Write data to Influx Database
if INFLUXDB=="1":
Write2InfluxDB(InfluxData)
if verbose=="1":
print("** Data written to InfluxDB: **")
print(json.dumps(InfluxData, indent=4, sort_keys=False, ensure_ascii=False))
# Write data to MQTT
if mqtt==1:
# Initialise MQTT connection
client=paho.Client("ViessmannMonitor")
if mqtt_tls=="1":
client.tls_set(mqtt_cacert,tls_version=mqtt_tls_ver)
client.tls_insecure_set(mqtt_tls_insecure)
client.username_pw_set(username=mqtt_username, password=mqtt_passwd)
client.connect(mqtt_server, mqtt_port)
# Send data to MQTT/Domoticz
client.loop_start()
for mqtt_data in DomoticzData:
result=client.publish(mqtt_topic, mqtt_data, retain=True)
result.wait_for_publish()
if not result.is_published:
print("Error publishing data for Domoticz to MQTT")
client.loop_stop()