# z_calibration Setup
#-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
#####################################################################
# URL Resource: https://github.com/protoloft/klipper_z_calibration
# Klipper set up AutoZ Guide: https://gist.github.com/conlank/7904ba9529a27b03d707d3a6417877df
#####################################################################
[z_calibration]
nozzle_xy_position: 202, 303.5 #202, 301
# A X, Y coordinate (e.g. 100,100) of the nozzle, clicking on the Z endstop.
switch_xy_position: 207, 278.5 #207, 276
# A X, Y coordinate (e.g. 100,100) of the probe's switch body, clicking on
# the Z endstop.
#bed_xy_position: 150, 153
# a X, Y coordinate (e.g. 100,100) where the print surface (e.g. the center
# point) is probed. These coordinates will be adapted by the
# probe's X and Y offsets. The default is the relative_reference_index
# of the configured bed_mesh, if configured. It's possible to change the relative
# reference index at runtime or use the GCode argument BED_POSITION of CALIBRATE_Z.
switch_offset: 0.2375 #0.3
# The trigger point offset of the used mag-probe switch.
# Larger values will position the nozzle closer to the bed.
# This needs to be find out manually. More on this later
# in this section..
max_deviation: 1.0
# The maximum allowed deviation of the calculated offset.
# If the offset exceeds this value, it will stop!
# The default is 1.0 mm.
#samples: default from "probe:samples" section
# The number of times to probe each point. The probed z-values
# will be averaged. The default is from the probe's configuration.
#samples_tolerance: default from "probe:samples_tolerance" section
# The maximum Z distance (in mm) that a sample may differ from other
# samples. The default is from the probe's configuration.
#samples_tolerance_retries: default from "probe:samples_tolerance_retries" section
# The number of times to retry if a sample is found that exceeds
# samples_tolerance. The default is from the probe's configuration.
#samples_result: default from "probe:samples_result" section
# The calculation method when sampling more than once - either
# "median" or "average". The default is from the probe's configuration.
clearance: 5
#clearance: 20
# The distance in mm to move up before moving to the next
# position. The default is two times the z_offset from the probe's
# configuration.
#position_min: default from "stepper_z:position_min" section.
# Minimum valid distance (in mm) used for probing move. The
# default is from the Z rail configuration.
#speed: 50
speed: 300
# The moving speed in X and Y. The default is 50 mm/s.
#lift_speed: default from "probe:lift_speed" section
# Speed (in mm/s) of the Z axis when lifting the probe between
# samples and clearance moves. The default is from the probe's
# configuration.
#probing_speed: default from "stepper_z:homing_speed" section.
# The fast probing speed (in mm/s) used, when probing_first_fast
# is activated. The default is from the Z rail configuration.
#probing_second_speed: default from "stepper_z:second_homing_speed" section.
# The slower speed (in mm/s) for probing the recorded samples.
# The default is second_homing_speed of the Z rail configuration.
#probing_retract_dist: default from "stepper_z:homing_retract_dist" section.
# Distance to retract (in mm) before probing the next sample.
# The default is homing_retract_dist from the Z rail configuration.
probing_first_fast: false
# probing_first_fast: true
# If true, the first probing is done faster by the probing speed.
# This is to get faster down and the result is not recorded as a
# probing sample. The default is false.
start_gcode: _SET_Z_CURRENT VAL=HOME
DETACH_PROBE
# A list of G-Code commands to execute prior to each calibration command.
# See docs/Command_Templates.md for G-Code format. This can be used to
# attach the probe.
before_switch_gcode: ATTACH_PROBE
G0 Z20
# A list of G-Code commands to execute prior to each probing on the
# mag-probe. See docs/Command_Templates.md for G-Code format. This can be
# used to attach the probe after probing on the nozzle and before probing
# on the mag-probe.
end_gcode: _SET_Z_CURRENT
DETACH_PROBE
# A list of G-Code commands to execute after each calibration command.
# See docs/Command_Templates.md for G-Code format. This can be used to
# detach the probe afterwards.