Table CWC made for WinCC Unified

Icon

1. CONTENT

HTML table

2. INTERFACE

  • columns : Array of element for the columns title
    // Example
    columns: ["Parameter", "Read", "Value"]
  • columnsEdit : Array of bool Flag to enable or diable (False / True) the text input area on a colum
    // Example
    columnsEdit: [false, false, true]
  • columnsShow : Array of bool Flag to hide or dhow (False / True) a colum
    // Example
    columnsShow: [true, true, true]
  • pageLength : Number of rows to be shown in one tab (i.e. 18)

  • rows : Array of element to fill the table rows

    // Example
    rows: [["param01", "read1", "value1"], ["param02", "read2", "value2"], ["param03", "read3", "value3"]],
  • searching : Flag to disable or anable (False / True) the search filed on top of the tabale (i.e. false)

  • select : Flag to diable or enable (False / True) the selcion of the rows (i.e. true)

3. EVENTS

  • ev_selectRow : This event is triggerd every time an user select or deselect a row, as a result if a row is selected in the "rowId" object is returned the content of the row with this structure:
    • rowId = Row first column value
    • rowVals = Array of values of all columns in the row
  • The column value is returned also if that colum is not visible
    // Example
    {"rowId":"param01","rowVals":["param01","read1","value1"]}
  • ev_updateRows : This event is triggerd every time an user update a row value by the text input area, as a result in the "rows" object is returned the updated content of the all the rows
    // Example
    [["param01", "read1", "value1"], ["param02", "read2", "value2"], ["param03", "read3", "value3"]]
  • ev_updateRow : This event is triggerd every time an user update a row value by the text input area, as a result in the "rows" object is returned the updated content of the all the updated row
    // Example
    ["param01", "read1", "value1"]

4. USAGE

  • OFFLINE MODE

    • You can test the behavior of the table with custom data by setting "production" to false
    • Now you can change all the data from "WebCC.Properties"
    var production = false;
    //...
    WebCC.Properties = {
      select: true,
      searching: false,
      columns: ["Parameter", "Read", "Value"],
      columnsEdit: [false, false, true],
      columnsShow: [true, true, true],
      rows: [["param01", "read1", "value1"],
             ["param02", "read2", "value2"],
             ["param03", "read3", "value3"]
            ],
      pageLength: 18
    };
  • ONLINE MODE (WinCC Unfied)

    • Set "production" to true
    var production = true;
    • To import the custom web control the hierarchy of folders and files must be compressed in ZIP format.
    • The name of the ZIP must be the GUID used the "manifest.json" file surrounded by curly brackets
      type": "guid://2823CFDE-FEE3-4B14-A792-96E2201EEAB8",
    • {2823CFDE-FEE3-4B14-A792-96E2201EEAB8}.zip

    • If you want this custom web control available for all your project, copy this file in the folder :

      • C:\Program Files\Siemens\Automation\Portal V17\Data\Hmi\CustomControls
      • replace "Porla V17" with your Tia version.
    • If you want to use this custom web control only in one project copy this file in the folder :

      • \path_to_tia_project\UserFiles
    • Refresh "My controls" to update the files in TIA Portal

    • Now you can place the custom web control in the Screen.