Problem description
Shomate thermodynamic properties only allows for 2 temperature ranges, but Cantera should allow 3 temperature ranges.
Steps to reproduce
See the attached input file example.yaml
example.yaml
import cantera as ct gas = ct.Solution('input/example.yaml')
The resulting error
--------------------------------------------------------------------------- CanteraError Traceback (most recent call last) Cell In[8], line 1 ----> 1 gas = ct.Solution('input/example.yaml') File build/python/cantera/base.pyx:71, in cantera._cantera._SolutionBase.__cinit__() File build/python/cantera/base.pyx:128, in cantera._canter [example.yaml.zip](https://github.com/Cantera/cantera/files/13185073/example.yaml.zip) a._SolutionBase._cinit() File build/python/cantera/base.pyx:215, in cantera._cantera._SolutionBase._init_yaml() CanteraError: ******************************************************************************* InputFileError thrown by AnyValue::checkSize: Error on line 17 of ./input/example.yaml: Expected array 'temperature-ranges' to have from 2 to 3 elements, but found an array of length 4. | Line | | 12 | species: | 13 | - name: H2 | 14 | composition: {H: 2} | 15 | thermo: | 16 | model: Shomate > 17 > temperature-ranges: [0.0, 1000.0, 2500.0, 6000.0] ^ | 18 | data: | 19 | - [33.066178, -11.36342, 11.432816, -2.772874, -0.158558, -9.980797, 172.708] | 20 | - [18.563083, 12.257357, -2.859786, 0.268238, 1.97799, -1.147438, 156.2881] *******************************************************************************
Behavior
Cantera should be able to deal with 3 temperature ranges. On NIST, H2 has 3 ranges: https://webbook.nist.gov/cgi/cbook.cgi?ID=C1333740&Mask=1#Thermo-Gas
System information
example.yaml.zip
The text was updated successfully, but these errors were encountered:
Thank you for the suggestion. I am transferring this over to the enhancement repository, as this is a feature request.
Sorry, something went wrong.
No branches or pull requests
Problem description
Shomate thermodynamic properties only allows for 2 temperature ranges, but Cantera should allow 3 temperature ranges.
Steps to reproduce
See the attached input file
example.yaml
The resulting error
Behavior
Cantera should be able to deal with 3 temperature ranges. On NIST, H2 has 3 ranges: https://webbook.nist.gov/cgi/cbook.cgi?ID=C1333740&Mask=1#Thermo-Gas
System information
example.yaml.zip
The text was updated successfully, but these errors were encountered: